天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

大鼠線粒體融合素2(MFN2)酶聯(lián)免疫吸附檢測試劑盒
ELK0352
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Rat MFN2(Mitofusin 2) ELISA Kit
Reactivity: Rat
Alternative Names: CMT2A; CMT2A2; CPRP1; HSG; MARF; Transmembrane GTPase MFN2
Assay Type: Sandwich
Sensitivity: 0.071 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;
Uniprot ID: Q8R500
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat MFN2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat MFN2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat MFN2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat MFN2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 1.961 1.875
5.00 1.520 1.434
2.50 1.121 1.035
1.25 0.907 0.821
0.63 0.492 0.406
0.32 0.389 0.303
0.16 0.211 0.125
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MFN2 and the recovery rates were calculated by comparing the measured value to the expected amount of MFN2 in samples.
Matrix Recovery range Average
serum(n=5) 95-108% 101%
EDTA plasma(n=5) 82-97% 89%
Heparin plasma(n=5) 84-93% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MFN2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 83-92% 92-96% 86-98% 95-101%
EDTA plasma(n=5) 95-102% 87-101% 82-91% 85-97%
Heparin plasma(n=5) 93-102% 78-92% 87-98% 80-93%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
江源县| 正阳县| 南宫市| 怀安县| 志丹县| 天峨县| 青州市| 长兴县| 额济纳旗| 叶城县| 陇川县| 胶南市| 鞍山市| 甘德县| 黄冈市| 永年县| 北碚区| 巴彦县| 都兰县| 金乡县| 方山县| 谢通门县| 濮阳县| 子长县| 鄂伦春自治旗| 贵南县| 开封县| 蒲城县| 阜新市| 东兴市| 汽车| 含山县| 华蓥市| 库尔勒市| 辉县市| 澄江县| 唐海县| 巴彦县| 乐清市| 祁阳县| 奎屯市|