天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人胎球蛋白A(FETUA)酶聯(lián)免疫吸附檢測試劑盒
ELK1207
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻

Product name: Human FETUA(Fetuin A) ELISA Kit
Reactivity: Human
Alternative Names: HSGa; A2HS; AHS; FETUA; HSG-A2; Fetuin-A; Alpha 2-HS Glycoprotein; Fetuin A; Alpha-2-Z-Globulin;? Ba-alpha-2-Glycoprotein; Alpha-2-Heremans Schmid Glycoprotein; aHSG
Assay Type: Sandwich
Sensitivity: 0.38 ng/mL
Standard: 50 ng/mL
Detection Range: 0.79-50 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Infection immunity;
Uniprot ID: P02765
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human FETUA. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human FETUA. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human FETUA, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human FETUA in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準曲線

Concentration (ng/mL) OD Corrected OD
50.00 2.079 1.996
25.00 1.556 1.473
12.50 1.128 1.045
6.25 0.801 0.718
3.13 0.614 0.531
1.57 0.305 0.222
0.79 0.235 0.152
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant FETUA and the recovery rates were calculated by comparing the measured value to the expected amount of FETUA in samples.
Matrix Recovery range Average
serum(n=5) 85-97% 91%
EDTA plasma(n=5) 82-97% 89%
Heparin plasma(n=5) 87-95% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of FETUA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-105% 82-95% 81-97% 93-105%
EDTA plasma(n=5) 85-97% 90-99% 82-101% 93-105%
Heparin plasma(n=5) 82-95% 88-102% 84-97% 89-107%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
奇台县| 潮州市| 依兰县| 武平县| 曲阳县| 祥云县| 射洪县| 泌阳县| 卢湾区| 神木县| 肥城市| 宣化县| 湘乡市| 新河县| 冕宁县| 丹东市| 苍梧县| 五寨县| 尼玛县| 杭锦后旗| 安多县| 九台市| 桂平市| 长白| 临清市| 丰宁| 利辛县| 那曲县| 沙河市| 永泰县| 巴南区| 保德县| 顺昌县| 宜州市| 白朗县| 丰宁| 肇东市| 双桥区| 蒙自县| 湘西| 富川|