Product name: Human MMP11(Matrix Metalloproteinase 11) ELISA Kit
Reactivity: Human
Alternative Names: SL3; ST3; STMY3; Stromelysin 3
Assay Type: Sandwich
Sensitivity: 0.27 ng/mL
Standard: 50 ng/mL
Detection Range: 0.79-50 ng/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Tumor immunity;Infection immunity;
Uniprot ID: P24347
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MMP11. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MMP11. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MMP11, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MMP11 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
50.00 2.075 1.986
25.00 1.502 1.413
12.50 1.174 1.085
6.25 0.963 0.874
3.13 0.492 0.403
1.57 0.385 0.296
0.79 0.168 0.079
0.00 0.089 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MMP11 and the recovery rates were calculated by comparing the measured value to the expected amount of MMP11 in samples.
Matrix Recovery range Average
serum(n=5) 77-95% 86%
EDTA plasma(n=5) 83-97% 90%
Heparin plasma(n=5) 81-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MMP11 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 87-96% 92-101% 82-95%
EDTA plasma(n=5) 95-102% 83-96% 97-105% 85-97%
Heparin plasma(n=5) 88-97% 96-105% 81-96% 93-107%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
莎车县| 涿鹿县| 桂林市| 安阳县| 嫩江县| 灵石县| 平定县| 清原| 邻水| 望奎县| 鄯善县| 商城县| 衡水市| 巩留县| 左贡县| 太湖县| SHOW| 陇川县| 凌源市| 布尔津县| 翁源县| 邮箱| 屏南县| 时尚| 安丘市| 喀喇沁旗| 洛川县| 达拉特旗| 衡阳市| 洛扎县| 黄骅市| 镇赉县| 台前县| 习水县| 温宿县| 开鲁县| 孝昌县| 博湖县| 琼中| 抚宁县| 临朐县|