天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

大鼠黃體激素(LH)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK2367
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Rat LH(Luteinizing Hormone) ELISA Kit
Reactivity: Rat
Alternative Names: ICSH; Lutropin; Interstitial Cell Stimulating Hormone
Assay Type: Sandwich
Sensitivity: 0.17 mIU/mL
Standard: 30 mIU/mL
Detection Range: 0.47-30 mIU/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Endocrinology;Reproductive science;Hormone metabolism;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat LH. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat LH. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat LH, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat LH in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (mIU/mL) OD Corrected OD
30.00 2.258 2.185
15.00 1.686 1.613
7.50 1.185 1.112
3.75 0.806 0.733
1.88 0.585 0.512
0.94 0.322 0.249
0.47 0.258 0.185
0.00 0.073 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant LH and the recovery rates were calculated by comparing the measured value to the expected amount of LH in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 78-92% 85%
Heparin plasma(n=5) 85-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of LH and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 92-101% 84-92% 78-90%
EDTA plasma(n=5) 91-98% 83-101% 87-98% 95-102%
Heparin plasma(n=5) 85-96% 85-101% 84-98% 85-93%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
建始县| 红河县| 黄梅县| 宣威市| 六盘水市| 安乡县| 长葛市| 平邑县| 丹阳市| 甘孜县| 平阳县| 靖州| 浦江县| 荃湾区| 乐山市| 德惠市| 海阳市| 襄汾县| 广东省| 黎城县| 衡山县| 普洱| 内黄县| 景东| 平和县| 二手房| 普宁市| 于田县| 绥芬河市| 永登县| 临邑县| 彭山县| 平顺县| 滁州市| 凤翔县| 娱乐| 盘山县| 上犹县| 临湘市| 望都县| 鸡东县|