天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人谷丙轉(zhuǎn)氨酶(ALT)酶聯(lián)免疫吸附檢測試劑盒
ELK2461
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Human ALT(Alanine Aminotransferase) ELISA Kit
Reactivity: Human
Alternative Names: GPT; ALAT; SGPT; AAT1; GPT1; Serum Glutamic Pyruvic Transaminase; Alanine Transaminase; Glutamate pyruvate transaminase 1; Glutamic--alanine transaminase 1
Assay Type: Sandwich
Sensitivity: 0.059 U/L
Standard: 10 U/L
Detection Range: 0.16-10 U/L
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Infection immunity;Hepatology;
Uniprot ID: P24298
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human ALT. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human ALT. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human ALT, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human ALT in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (U/L) OD Corrected OD
10.00 1.964 1.870
5.00 1.616 1.522
2.50 1.043 0.949
1.25 0.769 0.675
0.63 0.541 0.447
0.32 0.319 0.225
0.16 0.256 0.162
0.00 0.094 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant ALT and the recovery rates were calculated by comparing the measured value to the expected amount of ALT in samples.
Matrix Recovery range Average
serum(n=5) 83-95% 89%
EDTA plasma(n=5) 88-102% 95%
Heparin plasma(n=5) 79-97% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ALT and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-99% 93-107% 85-94% 87-101%
EDTA plasma(n=5) 86-97% 88-95% 92-101% 87-98%
Heparin plasma(n=5) 85-92% 79-96% 89-100% 85-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
广安市| 方城县| 白朗县| 甘德县| 合阳县| 黔江区| 新化县| 怀宁县| 英吉沙县| 北京市| 西林县| 福建省| 昆山市| 泾川县| 上犹县| 格尔木市| 开封县| 木里| 蓝山县| 敖汉旗| 浦北县| 岱山县| 称多县| 连云港市| 筠连县| 达拉特旗| 怀集县| 临漳县| 金门县| 壤塘县| 石楼县| 柘城县| 潞西市| 阳曲县| 天长市| 宜昌市| 红河县| 保定市| 铅山县| 镇雄县| 宁波市|