天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

小鼠沉默調(diào)節(jié)蛋白1(SIRT1)酶聯(lián)免疫吸附檢測試劑盒
ELK6397
規(guī)格: 價格:
48T ¥2240.00
96T ¥3200.00

Overview 文獻(xiàn)

Product name: Mouse SIRT1(Sirtuin 1) ELISA Kit
Reactivity: Mouse
Alternative Names: SIR2L1; Silent Mating Type Information Regulation 2 Homolog 1; NAD-Dependent Deacetylase Sirtuin-1; SIR2-like protein 1; SirtT1 75 kDa fragment
Assay Type: Sandwich
Sensitivity: 0.122 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Endocrinology;
Uniprot ID: Q923E4
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse SIRT1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse SIRT1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse SIRT1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse SIRT1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.056 1.973
10.00 1.657 1.574
5.00 1.186 1.103
2.50 0.852 0.769
1.25 0.559 0.476
0.63 0.361 0.278
0.32 0.302 0.219
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant SIRT1 and the recovery rates were calculated by comparing the measured value to the expected amount of SIRT1 in samples.
Matrix Recovery range Average
serum(n=5) 85-97% 91%
EDTA plasma(n=5) 80-92% 86%
Heparin plasma(n=5) 92-107% 99%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SIRT1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-98% 92-101% 82-98% 89-97%
EDTA plasma(n=5) 87-101% 87-96% 82-93% 89-97%
Heparin plasma(n=5) 85-93% 98-105% 87-98% 95-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
呼玛县| 古浪县| 井冈山市| 永新县| 运城市| 天津市| 天柱县| 吴川市| 呼伦贝尔市| 东乌珠穆沁旗| 乌鲁木齐县| 阳朔县| 吉林市| 勐海县| 静安区| 德钦县| 贵溪市| 曲水县| 溧阳市| 崇左市| 娄烦县| 上思县| 金平| 谷城县| 安多县| 本溪市| 扶绥县| 迁安市| 大田县| 汉寿县| 城固县| 综艺| 汝州市| 陆丰市| 礼泉县| 乌鲁木齐县| 浦江县| 虞城县| 凤凰县| 萨迦县| 容城县|