天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人含干擾素誘導(dǎo)解旋酶C域蛋白1(IFIH1)酶聯(lián)免疫吸附檢測試劑盒
ELK7252
規(guī)格: 價格:
48T ¥2240.00
96T ¥3200.00

Overview 文獻

Product name: Human IFIH1(Interferon Induced Helicase C Domain Containing Protein 1) ELISA Kit
Reactivity: Human
Alternative Names: Hlcd; IDDM19; MDA5; Helicard; Clinically amyopathic dermatomyositis autoantigen 140 kDa; Melanoma differentiation-associated protein 5; Murabutide down-regulated protein
Assay Type: Sandwich
Sensitivity: 0.12 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: Tissue homogenates, cell lysates and other biological fluids.
Assay Length: 3.5h
Research Area: Signal transduction;
Uniprot ID: Q9BYX4
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human IFIH1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human IFIH1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human IFIH1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human IFIH1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.172 2.076
10.00 1.643 1.547
5.00 1.174 1.078
2.50 0.728 0.632
1.25 0.496 0.400
0.63 0.276 0.180
0.32 0.241 0.145
0.00 0.096 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant IFIH1 and the recovery rates were calculated by comparing the measured value to the expected amount of IFIH1 in samples.
Matrix Recovery range Average
serum(n=5) 84-95% 88%
EDTA plasma(n=5) 82-97% 92%
Heparin plasma(n=5) 87-99% 94%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IFIH1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 82-95% 88-102% 84-97% 89-107%
EDTA plasma(n=5) 86-93% 91-105% 87-99% 99-105%
Heparin plasma(n=5) 86-95% 85-96% 89-100% 85-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
阳原县| 巴里| 二连浩特市| 宝丰县| 石城县| 双城市| 定襄县| 旬邑县| 临武县| 永泰县| 历史| 大渡口区| 德兴市| 昌图县| 昂仁县| 潜江市| 海门市| 隆子县| 富锦市| 都江堰市| 厦门市| 桐梓县| 杭锦旗| 西华县| 兴海县| 库伦旗| 贵定县| 新晃| 鸡西市| 文山县| 邯郸市| 富裕县| 福清市| 泸溪县| 普定县| 仁布县| 丰台区| 卢湾区| 楚雄市| 周至县| 南郑县|