天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

小鼠跨膜蛋白119(TMEM119)酶聯(lián)免疫吸附檢測試劑盒
ELK8672
規(guī)格: 價格:
48T ¥2240.00
96T ¥3200.00

Overview 文獻

Product name: Mouse TMEM119(Transmembrane Protein 119) ELISA Kit
Reactivity: Mouse
Alternative Names: PSEC0199;OBIF
Assay Type: Sandwich
Sensitivity: 0.052 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;
Uniprot ID: Q8R138
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse TMEM119. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse TMEM119. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse TMEM119, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse TMEM119 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.121 2.035
5.00 1.777 1.691
2.50 1.194 1.108
1.25 0.933 0.847
0.63 0.539 0.453
0.32 0.386 0.300
0.16 0.251 0.165
0.00 0.086 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TMEM119 and the recovery rates were calculated by comparing the measured value to the expected amount of TMEM119 in samples.
Matrix Recovery range Average
serum(n=5) 88-102% 95%
EDTA plasma(n=5) 92-105% 98%
Heparin plasma(n=5) 89-103% 96%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TMEM119 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 87-103% 97-105% 79-90%
EDTA plasma(n=5) 85-92% 87-103% 90-98% 95-102%
Heparin plasma(n=5) 88-97% 86-102% 91-103% 89-97%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
祁连县| 上蔡县| 汤原县| 普格县| 子洲县| 个旧市| 宜昌市| 蒙城县| 山阴县| 和田县| 广宁县| 普陀区| 潞城市| 宣汉县| 临朐县| 方山县| 兴义市| 巢湖市| 集贤县| 尼玛县| 桐城市| 永登县| 永定县| 都兰县| 南平市| 瓮安县| 金坛市| 黄龙县| 泰来县| 宝兴县| 务川| 安庆市| 南川市| 滦南县| 慈溪市| 永州市| 屯门区| 安徽省| 岑溪市| 武威市| 巨鹿县|