天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

人干擾素調(diào)節(jié)因子7(IRF7)酶聯(lián)免疫吸附檢測試劑盒
ELK9109
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Human IRF7(Interferon Regulatory Factor 7) ELISA Kit
Reactivity: Human
Alternative Names: Interferon regulatory factor 7; IRF-7; IRF7
Assay Type: Sandwich
Sensitivity: 0.048 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Immune molecule;
Uniprot ID: Q92985
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human IRF7. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human IRF7. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human IRF7, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human IRF7 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.258 2.160
5.00 1.572 1.474
2.50 1.043 0.945
1.25 0.782 0.684
0.63 0.468 0.370
0.32 0.366 0.268
0.16 0.212 0.114
0.00 0.098 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant IRF7 and the recovery rates were calculated by comparing the measured value to the expected amount of IRF7 in samples.
Matrix Recovery range Average
serum(n=5) 81-103% 87%
EDTA plasma(n=5) 80-97% 88%
Heparin plasma(n=5) 83-95% 89%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IRF7 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-102% 95-103% 88-96% 81-95%
EDTA plasma(n=5) 95-105% 88-102% 93-101% 93-106%
Heparin plasma(n=5) 89-97% 85-94% 83-95% 88-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
南岸区| 界首市| 阿瓦提县| 北安市| 邵武市| 正蓝旗| 汽车| 永年县| 那坡县| 菏泽市| 崇礼县| 类乌齐县| 邛崃市| 邯郸县| 亳州市| 镇平县| 临邑县| 观塘区| 德阳市| 明水县| 苏尼特右旗| 望奎县| 文登市| 阿巴嘎旗| 铜川市| 遂川县| 新竹县| 民县| 辛集市| 金川县| 太湖县| 麦盖提县| 南昌市| 花莲县| 鲁山县| 轮台县| 池州市| 色达县| 丰台区| 黑河市| 新蔡县|