天天摸天天碰天天添中文字幕,国产区点击进入在线影院,无码人妻一区二区免费AV,亚洲精品国产av现线

產(chǎn)品中心

小鼠沉默調(diào)節(jié)蛋白2(SIRT2)酶聯(lián)免疫吸附檢測試劑盒
ELK9507
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Mouse SIRT2(Sirtuin 2) ELISA Kit
Reactivity: Mouse
Alternative Names: SIR2L; SIR2-L; SIR2L2; Silent Information Regulator 2 Protein; NAD-Dependent Deacetylase Sirtuin-2; Silent Mating Type Information Regulation 2 Homolog
Assay Type: Sandwich
Sensitivity: 0.68 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Developmental science;
Uniprot ID: Q8VDQ8
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse SIRT2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse SIRT2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse SIRT2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse SIRT2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
100.00 2.096 2.003
50.00 1.607 1.514
25.00 1.211 1.118
12.50 0.813 0.720
6.25 0.538 0.445
3.13 0.335 0.242
1.57 0.252 0.159
0.00 0.093 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant SIRT2 and the recovery rates were calculated by comparing the measured value to the expected amount of SIRT2 in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 81-97% 89%
Heparin plasma(n=5) 84-97% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SIRT2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-96% 85-97% 82-93% 86-95%
EDTA plasma(n=5) 81-96% 92-101% 82-98% 89-102%
Heparin plasma(n=5) 89-97% 81-96% 93-106% 82-95%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
隆尧县| 称多县| 阿坝县| 博湖县| 贞丰县| 铜梁县| 濉溪县| 敖汉旗| 镇远县| 泰宁县| 西城区| 英德市| 满洲里市| 哈巴河县| 衡阳市| 通辽市| 通海县| 克山县| 绿春县| 东乌珠穆沁旗| 临西县| 福鼎市| 甘泉县| 公主岭市| 达日县| 南安市| 合水县| 营口市| 驻马店市| 庆阳市| 茌平县| 阿坝县| 日喀则市| 崇文区| 法库县| 集贤县| 海南省| 崇信县| 苏尼特左旗| 文登市| 灌阳县|